•Hold Status

OR

Image processing

NG Status

Image processing

OK Status

Image processing

NG Status

Image processing

NG Status

TEST

A

A: TEST minimum input time (1 ms or more)

The status condition is normally updated for each trigger. However, if the status is NG, the condition is unchanged
until input such as TEST is executed.
If one NG is detected, the OR output status remains NG from that point, regardless of the actual judgment results.
When the TEST input is turned on/off, the hold status is canceled and all terminals are reset to the normal state. The
OR output condition will be updated when the result for the next OR output is output.

•One Shot Output

OR

Image processing

NG Status

Image processing

NG Status

Image processing

OK Status

The OR output holds the NG state for the specified period of time, and then resets the NG state.
If image processing is continuously performed with One Shot Output enabled, the previous NG state may still be
remaining at the time the image processing judgment result is finalized by the STO.

A: One shot time (1 to 9999 ms)

A