The wiring connection of the external terminal of the CV‐X100 Series can be checked.

Click the button at the top right of the screen to switch to Setup Mode.

2. Checking the connection status of the external terminal (I/O Monitor)

Select "Utility" > "I/O Monitor" to open the I/O Monitor.

Check the box to set to ON (short circuit), and
uncheck it to set to OFF (open).

Manual Output can only be used in Setup Mode.

If proper ON/OFF status in conjunction with checking/unchecking the box cannot be confirmed, check the wiring

again.

Check the "Manual Output" box to forcefully turn selected output terminals ON, in order to confirm the signal on
the target.

Check the "OUT22 (STO)" and "OUT23 (OR)" boxes, and confirm that the ON/OFF status of the signal can be

detected on the target (PLC, relay, etc.). Check the box to set to ON (short circuit), and uncheck it to set to OFF

(open).