KEYENCE CV-X Series User Manual
Page 15
KEYENCE CORPORATION. Vision System Division
‐ 15 ‐
www.keyence.com
Example of connections
When connecting an NPN output PLC to the controller input
When connecting a PNP output PLC to the controller input
PLC (NPN output)
Input circuit on controller
PLC (PNP output)
Input circuit on controller
Output circuit diagram (NPN output type)
Output circuit diagram (PNP output type, controllers with a "P" at the end of the part number)
•
Maximum applied voltage: 30 V
•
Maximum sink current: 50 mA
•
Leakage current: 0.1 mA or less
•
Residual voltage:
1.4 V or less (50 mA)
1.0 V or less (20 mA)
•
Maximum applied voltage: 30 V
•
Maximum sink current: 50 mA
•
Leakage current: 0.1 mA or less
•
Residual voltage:
1.4 V or less (50 mA)
1.0 V or less (20 mA)
(No. 18, 19, 20)
(No. 17)
- GL-R Series (12 pages)
- GL-RHG Series (136 pages)
- GL-RHG Series (12 pages)
- GL-T11R (8 pages)
- SL-U2 (2 pages)
- SL-C Series (1 page)
- SL-V Series (10 pages)
- SL-V Series (168 pages)
- SL-C Series (54 pages)
- SL-M Series (8 pages)
- SL-T11R (6 pages)
- SL-VH1S (60 pages)
- SL-VHS Series (10 pages)
- SL-CHG Series (54 pages)
- SL-CHS Series (54 pages)
- SL-R11 (42 pages)
- SL-R11E (46 pages)
- SL-R12EX (76 pages)
- SJ Series (1 page)
- SJ-H Series (14 pages)
- SJ-HA Series (12 pages)
- SJ-HS/HW/HM (2 pages)
- SJ-F2000 Series (4 pages)
- SJ-F031 (10 pages)
- SJ-F300 Series (14 pages)
- SJ-F100W/100/010 (56 pages)
- SJ-M400 (14 pages)
- SJ-M100 (16 pages)
- SJ-M201 (16 pages)
- SJ-M300 (14 pages)
- CA-CNX10U (4 pages)
- CA-DC21E (2 pages)
- CA-HX048C (2 pages)
- CA-HX200C (2 pages)
- CA-HX500C (2 pages)
- XG Series (22 pages)
- XG VisionTerminal (58 pages)
- XG-8000 Series (12 pages)
- XG-8700T (12 pages)
- XG-7000 Series (8 pages)
- CA-H2100C (2 pages)
- CA-U4 (2 pages)
- CV-X Series (16 pages)
- CV-X Series (22 pages)
- CV-X Series (20 pages)