I/O terminal control (SS: Save Settings)
Saves the current Program Setting and Global Settings.
SS command: Save Settings
Save Settings
Sample SS command execution procedure
1. Set IN0 to 11 to OFF (open).
2. Set CST (IN12) to ON.
3. CMD_READY (OUT3) turns OFF, and the settings are saved.
4. When the settings are saved, ACK (OUT0) turns ON for the specified amount of time (set in "Global" >
"Communications & I/O" > "External Terminal"). When ACK turns off, CMD_READY (OUT3) turns ON.
* If the command execution fails, NACK (OUT1) turns on for the specified amount of time instead of ACK. Ensure that the
wiring and CMD_CODE/CMD_PARAM specifications are correct.
1: ON (short circuit), 0: OFF (open)
1: ON (short circuit), 0: OFF (open)
1: ON (short circuit), 0: OFF (open)