This section includes a time chart for each OR Terminal Output Mode
5. Timing Charts
•Update Every Judge
OR
STO
Image processing
NG Status
A
B
C
Select "Global" > "Communications & I/O" > "External Terminal".
A: Output rise time (1 to 999 ms)
B: Output time (1 to 999 ms)
C: Output change time (2 to 1000 ms)
However, ensure that "A + B ≦ C".
Changing the STO output time
When judgment is finalized, STO (OUT22) rises and the ON/OFF status of OR (OUT23) is checked simultaneously.
Adjust the output time for STO (A/B/C in the time chart) in global settings so that there is time for the target PLC to
detect the status.
Adjust A: Output rise time (1 to 999 ms), B: Output time (1 to 999 ms) and C: Output change time (2 to 1000 ms) so
that there is time for the target PLC to detect the status. However, ensure that "A + B ≦ C".
Image processing
NG Status
Image processing
OK Status