Select the terminal output mode for outputting Total Status from the OR Terminal.

Select "OR Terminal", and then set the "OR Terminal Output Mode" and "OR Terminal Output Timing".

4. Setting the OR Terminal Output Mode

OR Terminal Output Mode

•Update Every Judge: The terminal output state of the OR terminal is updated every time judgment is performed,
and is in accordance to the judgment result. It is synchronized with the leading edge of STO that is output every
time a judgment is finalized, and reads.
•Hold Status: When an NG Status is output, the NG status is retained, regardless of further judgment results.

•One Shot Output: The OR terminal turns on for the amount of time specified in "One Shot Time" and then turns
off.

OR Terminal Output Timing
•Output on NG Status
•Output on OK Status


Refer to the timing charts for each output mode on the following pages.