3 explicit messaging, Co mm u ni c a ting w ith t he fd -s s er ie s – KEYENCE DL-DN1 User Manual
Page 58

3-3 Explicit Messaging
3-30
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (FD-S) -
3
Co
mm
u
ni
c
a
ting
w
ith t
he FD
-S
s
er
ie
s
Nx10+4
73
Hysteresis
R/W
FD-SS02
001.0 000.0 to 200.0
FD-SF1(S)
0010 0000 to 1000
FD-SF1(F)
001.0 000.0 to 200.0
FD-SS2(S)
0010 0000 to 2000
FD-SS2(F)
001.0 000.0 to 200.0
FD-SF8(S)
00.10 00.00 to 08.00
FD-SF8(F)
0010 0000 to 2000
FD-SS20(S) 00.10 00.00 to 20.00
FD-SS20(F) 0010 0000 to 2000
74
Control Input
R/W
-
0
0: OFF
1: Bank change
2: Flow rate zero
3: Zero adjustment
4: Integration reset
75 to
7A
System reserved
7B
Power save mode
R/W
-
0
0: OFF
1: HALF
2: ALL
7C to
80
System reserved
81
Flow indicator color
R/W
-
1
0: Red for ON, green for OFF
1: Green for ON, red for OFF
82 to
83
System reserved
Nx10+5
64
Group-5 entry count
R
-
8
65 to
66
System reserved
67
Flow direction
*11
R/W
-
0
0: std
1: rEv
68
Integrated flow quantity
unit ("A"-free version)
R/W
FD-SS02
3
0: Cannot be set / 1: 0.1 / 2: 1 / 3: 10 / 4: 100 /
5: 1000 / 6: Cannot be set
FD-SS2
0: Cannot be set / 1: Cannot be set / 2:1 / 3:10 /
4: 100 / 5: 1000 / 6: 10000
FD-SS20
0: 0.01 / 1: 0.1 / 2: 1 / 3: 10 / 4: 100 /
5: Cannot be set / 6: Cannot be set
69 to
6A
System reserved
6B
Select volume/mass
flow rate
*11
R/W
-
1
0: Mass fl ow rate
1: Volume fl ow rate (specified density)
2: Volume flow rate (instantaneous density)
6C
Specify focus
*11
R/W
-
0
0: OFF
1: ON
6D to
83
System reserved
Nx10+6
64
Group-6 entry count
R
-
11
65
Product Code
R
-
-
FD-SA*A: Main unit: 4014
FD-SA*A: Expansion unit: 4015
FD-SA*: Main unit: 4012
FD-SA*: Expansion unit: 4013
66
Revision
R
-
-
0101h
67
Connected sensor
(capacity)
R
-
-
0: 0.2L
1: 2L
2: 20L
3: 1L
4: 8L
68
Connected sensor
(material)
R
-
-
0: SUS
1: PFA
InstID
(DEC)
AttrID
(HEX)
Name
Description Attribute
Sensor
head
Default
value
Parameter range