Error information list
Error ID
number
(HEX)
Error
code
(HEX)
Description
Cause
Corrective action
00h
01h
Initialization error
Error encountered during initial-
ization.
Check the number of con-
nected sensor amplifiers and
the connection to the sensor
amplifiers, and then cycle
power. If the error remains,
contact your nearest sales
office.
04h
Mixed connection error
A foreign sensor amplifier (i.e.,
one that is not compatible) is
connected.
Remove the foreign sensor
amplifier.
06h
Number-of-units error
More sensor amplifiers are con-
nected than are permitted.
Check the number of con-
nected sensor amplifiers.
nnh
(01h -
0Fh)
01h
Error 1 for sensor amplifier of
ID number nn
(Not used)
Refer to the FD-S series
instruction manual.
02h
Error 2 for sensor amplifier of
ID number nn
Head connection error
03h
Error 3 for sensor amplifier of
ID number nn
Overcurrent Error
04h
Error 4 for sensor amplifier of
ID number nn
EEPROM Error
05h
Error 5 for sensor amplifier of
ID number nn
No flow error
06h
Error 6 for sensor amplifier of
ID number nn
Backflow error
07h
Error 7 for sensor amplifier of
ID number nn
(Not used)
08h
Error 8 for sensor amplifier of
ID number nn
(Not used)
09h
Error 9 for sensor amplifier of
ID number nn
(Not used)
0Ah
Error 10 for sensor amplifier of
ID number nn
Drive gain error
0Bh
Error 11 for sensor amplifier of
ID number nn
Temperature low error
0Ch
Error 12 for sensor amplifier of
ID number nn
Temperature high error
1Dh
02h/
04-07h
System error
An error occurred in the internal
system.
Check the connection to the
sensor, and then cycle power. If
the error can not be corrected,
contact your nearest sales
office.
03h
Model error
There is a sensor amplifier con-
nected that is incompatible with
the DL-DN1.
Connect a sensor amplifier of a
compatible model.
1Fh
-
No error
-
-