100 mm, Frequency characteristic, Interference range – KEYENCE LB-1000(W) User Manual
Page 18

18
c
X
Y
b
X
Y
a
X
Y
CHARACTERISTICS (TYPICAL)
■ LB-301/LB-1201(W): 300 mm
±
100 mm
Shift-point adjustment range
Span adjustment range
Changes in detection span when target is tilted
The shift-point adjustment range shows the range where the output
voltage reading can be shifted to zero using the SHIFT adjustment
trimmer (operates when DIP switch 4 is set to LOCK). The AUTO
ZERO function (operates when DIP switch 4 is set to FREE), allows 0.V
resetting at any position within the measuring range.
Analog output
voltage (dB)
0
-10
-20
-30
100
1 K
Frequency (Hz)
915 Hz (-3dB)
Analog output
voltage (dB)
0
-10
-20
-30
10
100
Frequency (Hz)
36 Hz (-3dB)
LB-041
40 mm
20 mm
40 mm
LB-081
50 mm
30 mm
80 mm
LB-301
200 mm
180 mm
290 mm
■ Frequency characteristic
Common to LB-1001(W), LB-1101(W), and LB-1201(W)
RESPONSE speed selector switch set to HIGH
RESPONSE speed selector switch set to MID
RESPONSE speed selector switch set to LO
■ Interference range*
* Use of the interference suppression function enables close mounting
of 2 sensors. Since sensors “X” and “Y” alternately emit a laser beam
at 30 Hz, interference does not occur. (Target: white paper)