Key lock, Initialization, Switching between display screens – KEYENCE LR-TB5000 Series User Manual
Page 8: Display screen, How to switch the display, 5 useful functions
8
5 Useful Functions
Key Lock
To require a password to release the key lock, see
Initialization
Initialization resets the product to its factory default settings. After initialization, you will
have to configure the
"3 Initial Settings" (page 3).
Using the shortcut keys to execute the initialization
Using the setting menu to execute the initialization
On the "Initialize?" screen, select "Yes".
"6 Detailed Settings" (page 9)
Switching between Display Screens
You can select between four different displays.
Display screen
How to switch the display
*
When the output changes from ON to OFF, the bottom value is reset to the current
value.
When the output changes from OFF to ON, the peak value is reset to the current
value.
When the analog output [Analog] is selected, pressing [DISP/
S
] or [MODE/
T
] resets
both the bottom value and the peak value to the current value.
9999
Input Password
0000
0000
...
1567
1234
XX-XXXX
DISP
MODE
1
2
1567
1234
XX-XXXX
DISP
MODE
1
2
Press these buttons at the same time for 3 seconds or more.
If necessary, enter the password to release the lock.
Lock
Unlock
1567
1234
XX-XXXX
DISP
MODE
1
2
Initialize ?
No
Initialize ?
Yes
While pressing the [MODE/T] button, press the [SET]
button five times.
1234
1789
1
2
Use the I/O selection to change what is displayed here.
" 3-1. I/O Selection" (page 4).
(1): Output 1 (displayed in gray when OFF)
(2): Output 2 (displayed in gray when OFF)
A: Current
output
V: Voltage
output
IN: External input (displayed in gray when OFF)
An arrow will be displayed next to the setting value to be changed
when tuning or calibration is implemented.
Current value
Setting value
(the display of which
can be changed)
The indicator will turn grey while the
[DISP /S] button is pressed.
The indicator will turn grey while the
[MODE /T] button is pressed.
1567
1234
XX-XXXX
DISP
MODE
1
2
1567
1234
1
2
1567
1234
1789
1
2
P
B
1567
1
2
Simple
Display
S
Bar
Display
S
Peak Bottom
Display
S
Standard
Display
S
1567
MIN
1
2
MAX
Press the [DISP /S] button
(for 3 seconds or more).
Current value
Setting value
Current value
Peak value*
Bottom value*
Current value
Bar
Current value