beautypg.com

1. datum mode (fgs), Operation, Setting – KEYENCE LR-TB5000 Series User Manual

Page 5: 2. distance mode (bgs), 4 detection mode, Completion

background image

5

4 Detection Mode

The LR-TB Series has four output modes and three detection modes.

When the output modes for Out1 & Out2 are either [Standard] or [Window], the detection
modes can only be set in the below combinations.
[Out1] / [Out2] = [DATUM]/ [DATUM], [Distance]/ [Distance], [Distance]/ [Window],
[Window]/ [Distance], [Window]/ [Window]

4-1. DATUM Mode (FGS)

„

Operation

• In this mode, the change in position from a reference surface (which has a value of 0) is

displayed.

• This mode is useful in detecting the passage of workpieces in front of a stationary

background.

„

Setting

• Set the output mode to [Standard], which is the default mode.

"6 Detailed Settings"

(page 9)

• For details on setting output 2, see

" 4-5. Switching Out1/Out2" (page 7).

• In DATUM mode, a "±" is displayed in front of the setting value.

4-2. Distance Mode (BGS)

„

Operation

• In this mode, the distance from the sensor is displayed.

„

Setting

• Set the detection mode to [Standard], which is the default value.

"6 Detailed

Settings" (page 9)

• For details on setting output 2, see

" 4-5. Switching Out1/Out2" (page 7)

z

2-point calibration

Output Mode (

page 10)

Detection Mode

Standard (default value) [Standard]

4-1. DATUM mode (FGS)

4-2. Distance mode (BGS)

Window [Window]

4-3. Window mode

Stability [Stability]

(

page 10)

Error [Error]

(

page 10)

1567

1234

XX-XXXX

DISP

MODE

1
2

A

-A

0

ON

ON

N.O.

N.C.

OFF

OFF

Hys.

Hys.

A: Setting value

Hys: Hysteresis (

page 11)

Reference surface

1567

1234

XX-XXXX

DISP

MODE

1

2

1567

1234

XX-XXXX

DISP

MODE

1

2

ON

A

-A

ON

N.O.

N.C.

OFF

OFF

1

2

Reference surface

Press the set button for 1 second or less.

Press and hold the set button for 3 seconds or more.

Completion

1567

1234

XX-XXXX

DISP

MODE

1
2

Hys.

ON

ON

A

0

5000

N.O.

N.C.

OFF

OFF

A: Setting value

Hys: Hysteresis (

page 11)

1567

1234

XX-XXXX

DISP

MODE

1

2

1

2

1567

1234

XX-XXXX

DISP

MODE

1

2

1567

1234

XX-XXXX

DISP

MODE

1

2

ON

ON

N.O.

N.C.

OFF

OFF

Press the set button for 1 second or less.

Setting value

Press the set button for 1 second or less.

Completion