1. response time, Lr-tb5000/lr-tb5000c, Lr-tb5000cl – KEYENCE LR-TB5000 Series User Manual
Page 10: 2. output logic, 3. output mode, Standard [standard, Window [window, Stability [stability, Error [error, 4. timer
10
6-1. Response Time
Longer response times lead to more stable detection.
LR-TB5000/LR-TB5000C
LR-TB5000CL
6-2. Output Logic
Select N.O. or N.C. for the output logic. For details, see
6-3. Output Mode
Standard [Standard]
The output is activated according to the detecting distance. For details, see
Window [Window]
The output is activated according to the detecting distance. For details, see
Stability [Stability]
This function can be used to check whether there has been a decrease in the amount of
light received due to problems such as dirt on the detected surface.
z
When the I/O selection is [Out1 + Out2]
Output is activated if the amount of light received falls below the threshold (fixed value)
during the observation period.
Example) Chart during DATUM mode
z
When the I/O selection is [Analog]
Output is generated if the amount of light received falls below the threshold (fixed
value) for 5 seconds or more.
Error [Error]
Output is activated when an error occurs. When the error is cleared, the output is also
automatically reset. For causes of errors, see
6-4. Timer
This function can be used to delay the timing with which the sensor output is switched.
• Off delay [Off-delay]
• On delay [On-delay]
• One shot [One shot]
Detecting
distance
[mm]
Repetition Accuracy [mm] (Typical) (Under stable temperature)
White Paper (Reflectivity: 90%)
Response Time[ms]
1
10
25
100
1000
1000
±7
±3
±3
±3
±3
5000
±42
±12
±9
±5
±3
Detecting
distance
[mm]
Repetition Accuracy [mm] (Typical) (Under stable temperature)
Gray Paper (Reflectivity: 18%)
Response Time[ms]
1
10
25
100
1000
1000
±11
±4
±3
±3
±3
5000
±154
±40
±29
±14
±6
Detecting
distance
[mm]
Repetition Accuracy [mm] (Typical) (Under stable temperature)
White Paper (Reflectivity: 90%)
Response Time[ms]
2
20
50
200
2000
1000
±9
±6
±6
±3
±3
5000
±42
±14
±10
±5
±5
Detecting
distance
[mm]
Repetition Accuracy [mm] (Typical) (Under stable temperature)
Gray Paper (Reflectivity: 18%)
Response Time[ms]
2
20
50
200
2000
1000
±12
±6
±4
±3
±3
5000
±159
±42
±31
±15
±8
Detection Mode
Observation Period
DATUM
Negative setting value < detected value
< positive setting value
Distance
Detected value < setting value
Window
LOW-side setting value < detected value
< HIGH-side setting value
NEAR
FAR
1567
1234
XX-XXXX
DISP
MODE
1
2
ON
OFF
Distance
Setting value
Amount of
received light
(workpiece
background)
Amount of
received light
threshold (fixed)
Stability
output
(N.O.)
5 cycles
ON
OFF
ON
N.O.
N.C.
FAR
NEAR
OFF
ON
OFF
ON
N.O.
N.C.
OFF
ON
OFF
ON
N.O.
N.C.
OFF
ON
OFF
ON
N.O.
N.C.
OFF
Timer OFF
Off Delay
On Delay
One Shot
Timer time