Package contents, Specifications, Part functions – KEYENCE LR-TB5000 Series User Manual
Page 2: Installation, Wiring, Out1+out2, Input+out1, 2 installation and wiring
2
Package Contents
• Main unit
• Instruction manual
• Laser warning and explanation labels (LR-TB5000/LR-TB5000C only)
Specifications
*1
The range for displayable distance is from 50 to 5200.
*2
The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in
accordance with the requirements of Laser Notice No.50.
*3
150mA or less (with load)
*4
You can select the I/O from the following combinations.
Control output × 2, control output + external input, control output + analog output,
external input + analog output
(For details on the setting method, see
page 3 of the instruction manual.)
*5
IO-Link specification v.1.1/COM2 (38.4 kbps) is supported.
You can download a setup file from the KEYENCE website (http://www.keyence.com).
If you are using the product in an environment in which you cannot download files
over the Internet, contact your nearest KEYENCE office.
Part Functions
For a more detailed explanation, see
"Switching between Display Screens" (page 8).
2 Installation and Wiring
Installation
• Tightening torque for the mounting holes: 1.5 N·m (M4 screw)
• If the detecting object has a mirrored surface, install the sensor in a position where
specular reflection will not penetrate the optical receiver.
Wiring
With the LR-TB Series, you can select the functions of the I/O wires (black and white) from
the combinations shown below during the initial settings.
Independently isolate any I/O wires that you will not use.
Out1+Out2
z
NPN
z
PNP
Input+Out1
z
NPN
z
PNP
Model
Cable
LR-TB5000
-
Cable with
connector M12
LR-TB5000C
LR-TB5000CL
Detectable distance
*1
60 to 5000 mm
Spot diameter
Variable (use a spot diameter of 40 mm or less)
Response time
1 ms/10 ms/25 ms/
100 ms/1000 ms
selectable
2 ms/20 ms/50 ms/
200 ms/2000 ms
selectable
Light source
Type
Red laser (660 nm)
Laser class
Class 2 laser product
IEC60825-1,FDA(CDRH)
Part1040.10
*2
Class 1 laser product
IEC60825-1,FDA(CDRH)
Part1040.10
*2
Mutual interference prevention
function
4 units (when using the interference prevention function)
Timer
OFF/OFF delay/ON delay/One-shot
Power voltage
20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS
Current consumption
50 mA or less (without load)
*3
I/O
*4*5
Control output
NPN open collector/PNP open collector selectable
30 VDC or less, 50 mA or less,
Residual voltage: 2 V or less, N.O./N.C. selectable
External input
Transmission OFF / Tuning /
Reference surface update selectable
Short-circuit current: 1 mA or less for both NPN and PNP
For the applied voltage, see the wiring diagrams
(
page 2 in the instruction manual).
For the input times, see the time charts
(
page 4 in the instruction manual).
Analog output
Current output / Voltage output selectable
Current output: 4 to 20 mA with a max. load resistance
of 500 Ω
Voltage output: 0 to 10 V with an external load resistance
of 5 kΩ or more
Protection circuit
Protection against reverse power connection,
power supply surges, output overcurrent, output surge,
and reverse output connection
Environmental
resistance
Enclosure rating
IP65/IP67 (IEC60529)
Ambient light
Incandescent lamp/Sunlight: 100000 lux or less
Ambient
temperature
-20 to +55°C (no freezing)
Ambient humidity
35 to 85%RH (no condensation)
Shock resistance
1000m/s
2
in X, Y, Z axis directions respectively 6 times
Vibration resistance
10 to 55 Hz Double amplitude 1.5 mm in the X, Y, Z axis
directions respectively, 2 hours
Material
Case: Zinc die cast (Nickel chrome plating), Indicator cover
and buttons: PES, Lens cover and display: PMMA
(scratch-resistant coating specifications),
Cable bushing: PBT, Cable: PVC,
M12 connector (only for the cable with connector M12 type):
TPE, PBT, Nickel-plated brass
Weight
Cable type: Approx. 200 g (Including cable)
Cable with connector M12 type: Approx. 160 g
1567
1234
XX-XXXX
DISP
MODE
1
2
Indicator
Output 1 ON : Orange*
Output 1 OFF : Green*
Error
: Flashing red
* The indicator flashes when two conditions below
are met;
• Stability output turns ON (
page 10).
• Output 1 turns OFF when output logic is N.O. or
turns ON when output logic is N.C.
[SET] Button
The operation of this button varies
depending on the detection mode
(
page 5).
Example: 2-point calibration
1. Press this button with no workpiece
present.
2. Press this button with a workpiece
present.
[DISP/S] Button
Pressed for 1 second or less:
Changes the setting value (
Held for 3 seconds or more:
Switches to the display screen (
[MODE/T] Button
Pressed for 1 second or less:
Changes the setting value (
Held for 3 seconds or more:
Switches to the setting screen (
Load (input device)
Analog current or voltage input device
1, brown
4, black
2, white
3, blue
20 ... 30 V
0 V
1, brown
4, black
2, white
3, blue
20 ... 30 V
0 V
1, brown
4, black
2, white
3, blue
20 ... 30 V
0 V
1, brown
4, black
2, white
3, blue
20 ... 30 V
0 V