1. i/o selection, 2. external input selection, Transmission off [laser off – KEYENCE LR-TB5000 Series User Manual
Page 4: External calibration [tuning, Reference surface update [datum preset, 3. analog selection, 4. analog lower and upper limits, Current output (4 to 20 ma), Voltage output (0 to 10v), 5. npn/pnp selection
4
3-1. I/O Selection
Select from the following table the functions assigned to the I/O wires (black and white).
The functions assigned to output 1, output 2, and external input can be changed after you
finish configuring the initial settings.
"6 Detailed Settings" (page 9).
*
Would be fixed to transmission OFF.
3-2. External Input Selection
Transmission OFF [Laser Off]
The laser beam transmission is stopped.
External Calibration [Tuning]
When selected, this external input performs the same function as pressing the [SET]
button.
Reference surface update [DATUM Preset]
When the detection mode (
"4 Detection Mode" [page 5]) is set to "DATUM mode," this
external input updates the reference surface.
3-3. Analog Selection
Select from the following values.
• Current output: 4 to 20 mA
• Voltage output: 0 to 10 V
3-4. Analog Lower and Upper Limits
Configure scaling settings, if necessary.
Current output (4 to 20 mA)
z
Initial settings
z
When settings are changed
(example)
For details on the analog output when an error occurs, see
Voltage output (0 to 10V)
Initial settings
When settings are changed
(example)
For details on the analog output when an error occurs, see
3-5. NPN/PNP Selection
You can select between NPN outputs or PNP outputs. For details, see
Options
Black Wire
White Wire
Out1 + Out2
Output 1
Output 2
Input + Out1
External input
Output 1
Out1 + Analog
Output 1
Analog output
Input + Analog
External input*
Analog output
Transmission
Transmission
OFF
Input
ON
< 5 ms
< 50 ms
OFF
Input
ON
> 60 ms
> 60 ms
OFF
Updated reference surface
Updated output
Input
ON
> 5 ms
< 60 ms
Response
time
OFF
20.5 mA
20 mA
4 mA
0 50
5000
3.8 mA
20.5 mA
20 mA
4 mA
0
2000
4000
3.8 mA
20.5 mA
20 mA
4 mA
0
2000
4000
3.8 mA
Analog 4 mA
0
Analog 20 mA
5000
Analog 4 mA
4000
Analog 20 mA
2000
Analog 4 mA
2000
Analog 20 mA
4000
10 V
0 50
5000
0 V
10 V
0
2000
4000
0 V
10 V
0
2000
4000
0 V
Analog 0V
2000
Analog 10V
4000
Analog 0V
4000
Analog 10V
2000
Analog 0V
0
Analog 10V
5000