Learn feature (fill), Pause feature (fill), Changing targets from the weigh mode (fill) – Holtgreven GSE-375 User Manual
Page 47: Example (fill), Atch
41
See Pre-acts (General) on page 37 for details on the operational functions of pre-acts.
Learn Feature (Fill)
Pre-act 2 has a learn feature available which allows the Model 370/375 to adjust the final cutoff
based on changing environmental conditions. See Learn Feature (General) on page 37
for 'learn'
feature details.
Pause Feature (Fill)
The standard pause feature (keypress, remote key closure or both) is available for the fill
operation. See Pause Feature (General) on page 37
for 'pause' function details.
Changing Targets From The Weigh Mode (Fill)
When fill is configured in the setpoint setup, Targ1 automatically becomes an available mode for
the [SELECT] key. An entry followed by [TARE] or [SAMPLE/Enter] changes Targ 1. Pressing
[TARE] or [SAMPLE/Enter] alone allows access to the subsets. PA 1 and PA 2 are the subsets
for Targ 1. The pre-acts can be deleted as subsets by choosing 'disabled' at P5114 and P5115.
See Changing Targets from the Weigh Mode (General) on page 38 for instructions on changing
target values from the Weigh Mode.
Example (Fill)
With a system set up to fill 55-gallon drums with motor oil, the following settings might be used to
achieve an accurate final fill weight of 400 lbs.:
Parameter Setting
Actual Cutoff Value
Comments
Targ 1 = 400
Desired final weight.
Pre-act 1 = 28
400 – 28 = 372.0
Switch to dribble feed at 372.
Pre-act 2 = .5
400 – 0.5 = 399.5
Final fill valve closes at 399.5.
B
ATCH
The standard batch program is used for batching up to three separate items. Ingredients 1
through 3 use setpoints and pre-acts 1 through 3 respectively. Ingredients are batched one at a
time.
Table 3-7: Setpoint Setup (Batch)
Setpoint Selection
Function
Description
P5100.3
Batch
2 or 3 ingredient batching.
P5101.--
Targ1
Ingredient 1 target value.
P5104.0 Based Select
from
net or count (quantity).
P5105.--
PA 1
Pre-act 1 value (final cutoff for ingredient 1).
P5106.1
Learn 1
Learn feature for pre-act 1 enabled.
P5107.0
Start 1
Setpoint 1 activation method.
P5108.--
Targ 2
Ingredient 2 target value.
P5109.--
PA 2
Pre-act 2 value (final cutoff for ingredient 2).
P5110.1
Learn 2
Learn feature for pre-act 2 enabled.
P5111.0
Start 2
Setpoint 2 activation method.
P5116.1
Pause
Keypad press invokes pause mode.
P5117.--
Targ 3
Ingredient 3 target value.
P5118.--
PrAc 3
Pre-act 3 value (final cutoff for ingredient 3).
P5119.1
Learn 3
Learn feature for pre-act 3 enabled.
P5120.0
Start 3
Setpoint 3 activation method.