Chapter 3, Cale, Onfiguration – Holtgreven GSE-375 User Manual
Page 21
15
Chapter 3:
S
CALE
C
ONFIGURATION
This chapter will cover the configuration of the scale parameters and how to configure options
such as analog output, setpoint and communication modules.
E
E
n
n
t
t
e
e
r
r
i
i
n
n
g
g
t
t
h
h
e
e
S
S
e
e
t
t
u
u
p
p
M
M
o
o
d
d
e
e
(
(
M
M
o
o
d
d
e
e
l
l
3
3
7
7
0
0
)
)
To prevent accidental changes to the Model 370/375 Setup, a sequence of keystrokes is used to
gain access to the Setup Mode. If the Model 370 is set for remote display, unplug the unit and
press [ZERO] + [SELECT] upon power up. Follow the instructions below to access the setup
mode.
[ZERO] + [SELECT]
[SELECT], [ZERO], [PRINT], [UNITS], [TARE]
These keystrokes must be made within five seconds, or the Model 370 will return to the Weigh
Mode.
To access the Setup Mode:
1. From the Weigh Mode, press [ZERO] + [SELECT]
DISPLAY READS Setup ~ Enter Code
2. Press
[SELECT]
DISPLAY READS .
3. Press
[ZERO]
DISPLAY READS ..
4. Press
[PRINT]
DISPLAY READS …
5. Press
[UNITS]
DISPLAY READS ….
6. Press
[TARE]
DISPLAY READS Chgs ~ Poss!
P110.- - ~ F.S.= ~ 100
To access Setup in a view-only mode:
1. From the Weigh Mode, press [ZERO] + [SELECT]
DISPLAY READS Setup ~ Enter Code
2. Press
[TARE]
DISPLAY READS No ~ Chgs
P110.- - ~ F.S.= ~ 100
When exiting the Setup Mode, the Model 370/375 prompts whether to enter the Calibration
Mode. (See page 61 for Calibration Mode procedures). The display will then prompt to save
any changes.