Holtgreven GSE-375 User Manual
Page 41

35
If a combination of format choices is required, add the choice numbers together and enter their
sum as the format code. For example, to print the net weight without the name (Net) or units (lb)
and to print it minimum width:
NOTE: Only one of the choices 0-3 may be used at one time.
Choice
Sample Print Result
Description
3
“336.52 lb Net”
Minimum possible width.
32
“336.52 Net”
Do NOT print parameter units.
128
“336.52 lb”
Do NOT print parameter name.
Use the sum of the desired choice selections:
3 + 32 + 128 = 163
163
“336.52”
Minimum possible width.
Do NOT print parameter units.
Do NOT print parameter name.
Exiting Setup Mode And Saving Changes
Each custom transmit file must end with:
%z%c%e%e
This exits the Setup Mode, bypasses the calibration procedure and saves the Model 370/375
configuration file.
A
A
n
n
a
a
l
l
o
o
g
g
O
O
u
u
t
t
p
p
u
u
t
t
P
P
a
a
r
r
a
a
m
m
e
e
t
t
e
e
r
r
S
S
e
e
t
t
u
u
p
p
Analog output setup parameters beginning at P171 - P177 are used to setup the output module.
Parameter
Setting
Displayed
Name
Description
Type/choices (*=Default)
P171.00
AnAlg
Enable analog option.
Disbl*, Enabl
P172.00
AnPar
Parameter that analog signal corresponds to.
Displayed corresponds to gross while viewing the
gross weight and net otherwise.
Gross*, Net, Displayed
P173.--
AnlFS
Full scale value at which P172 selection yields an
output of 10 volts. If set to 0, uses P110 setting.
Numeric Entry:
0* to ±1,000,000
P174.--
AnOff
Offset value which yields a 0 volt output.
Numeric Entry:
0* to ±1,000,000
P175.10
AnRng
Range Value (1-10) which specifies the max value of
analog output – entered in terms of voltage. NOTE:
This does not change the analog span. A 0-10,000
lb. output set to 8 will stop increasing its analog
signal at 8,000 lbs.
Numeric entry:
0 to 10*
P176.01
AnRst
Reset state – Specifies analog signal level when
Model 370 and Model 375 enters Setup Mode.
10 V (Max Output)
0 V (Min Output)
No Change*
P177.00
AType
Specifies output type: voltage or current.
0 –10 volts*,
0 -20mA,
4 -20mA
A
NALOG
O
UTPUT
E
XAMPLE
Parameter
Setting
Parameter
Description
Example
Value
Comments
P172.01
Net Weight
3.00 lb
Current net weight.
P173.--
Analog Full Scale
20
Net weight value that would give maximum analog output.
P174.--
Zero Offset
-40
Net weight value that would give minimum analog output.
P175.--
Max Range Value
8
Maximum analog output allowed (entered in terms of voltage).