Panasonic WV-CPR650 User Manual
Page 35
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
2. After confirming the cursor is on LL, press El •
The vertical phase adjustment menu appears on
the monitor.
5.
6
.
3. Move the cursor to COARSE. The cursor starts
blinking.
4. Supply the video output signal of the camera to be
adjusted and the reference camera video output
signal to a dual-trace oscilloscope.
Set the oscilloscope to the vertical rate and
expand the vertical sync portion on the oscillo
scope.
Press ^ or to match the vertical phase for
both video output signals as closely as possible.
(COARSE adjustment can be incremented in 16
steps by 22.5degrees by pressing €1 or [^.)
1 (1 - - 16): 0 degrees
2 (1 - - 16): 22.5 degrees
16 (1 - - 16): 337.5 degrees
_____ I
Note: After the sixteenth step, the adjustment
returns to the first step.
7. Move the cursor to FINE. The cursor starts blink
ing.
8. Press ^ or to match the vertical phase for
both video output signals as closely as possible.
(FINE adjustment can be made up to 22.5 degrees
by pressing ^ or [^.)
Notes:
• When the 'T' cursor reaches the "-i-” end, it
jumps back to At the same time, COARSE
is incremented by one step to enable a contin
uous adjustment. The reverse takes place
when the "I" cursor reaches the end.
• When €1 or is kept pressed for a second
or longer, the “I" cursor moves faster.
-33-