beautypg.com

Dillon FI-521 User Manual

Page 7

background image

FI-521 Indicator Operation & Service Manual

────────────────────────────────────────────────────────

7

2. Specification

2.1 Housing and Outline Dimension

1.2.1 IP65 wash-down stainless steel housing with adjustable bracket

1.2.2 Outline Dimension:

With bracket: 10.3" x 8.5" x 3.8" (262mm x 215mm x 96mm)
Without bracket: 8.9" x 6.3" x 3.8" (225mm x 160mm x 96mm)















Front View Side View Back View

2.2 Power Supply

2.2.1 12 Vdc / min.500mA output AC adapter


2.3 Display:

2.3.1 FI-521: 7-digits,7-segment, 0.7’’(17mm) ultra brightness LEDs with 14 annunciators.

2.4 Keypad: 6 push buttons of SELECT, CELL, PRINT, UNIT, ZERO, ON/OFF

2.5 Environment:

2.5.1 Working temperature: -10°C to 40°C
2.5.2 Storage temperature: -20°C to 70°C
2.5.3 Humidity: 10 to 90% RH without condensation
2.5.5 Protection: IP65

2.6 Load cell Excitation:
2.6.1 Voltage: 5Vdc
2.6.2 Max. Current: 120mA (can power 8-350 ohm bridge)

2.6.3 Signal connection: 4 or 6 lead with sense leads
2.6.4 Max Sensitivity: -3mV/V to +3mV/V

2.7 Communication:

2.7.1 Serial port1: Full-duplex RS232
2.7.2 Serial port2: Full-duplex RS232 or half-duplex RS485
2.7.3 Baud Rate: Selectable: 1200-2400-4800-9600-19200-22800/38400-57600 bps
2.7.4 Data Output Format: 8N1, 7O1, 7E1
2.7.5 Protocol: selectable


2.8 Analog Circuit characters:
2.8.1

24-bit

A/D

converter

2.8.2 Conversion Speed: 80Hz