Dillon FI-521 User Manual
Page 11
FI-521 Indicator Operation & Service Manual
────────────────────────────────────────────────────────
11
5. Operation Menu Structure
5.1 Main menu:
(Cell)
(Cell) (Cell) (Cell) (Cell)
NOTE:
(1) Each LOAD CELL has its own CONFIG, CAL, IN.OUT parameters, so, before you enter
this main menu select, which load cell will be configured with the CELL key!
(2) The parameters of USER, MISC, and TEST are the same for all load cells
(3) When “Lo.VoL” or “Lo.BAT” is displayed (the voltage to PCB is low), CONFIG, USER,
CAL, IN.OUT menu can not be entered and edited.
5.2 CONFIG Submenu:
5.2.1 Access the set up mode by pressing and holding the SELECT key for 3 seconds, until display shows
CONFIG.
5.2.2 Press
the
ZERO key once (ZERO key is your Enter key)
5.2.3 Display will show CFG.ON or CFG.OFF
a. If it shows CFG.OFF, then you will need to move the switch in the back of the indicator,
through the CAL. Switch cover. Cycle power of the indicator and start at step #1 again.
5.2.4 Press
the
ZERO key once. Display shows RESET
5.2.5 Pres
the
CELL key until display shows CELL.TY
5.2.6 Press
ZERO key once. Display shows TS.CP
5.2.7 Press
ZERO key once. Display shows CELL.TY
5.2.8 Press
CELL key once. Display shows DSP.POL
5.2.9 Press
ZERO key once. (Select NEG or POS)
5.2.10 Press ZERO to accept
5.2.11 Press CELL key to PRIM.N
5.2.12 Press ZERO key. Display shows 10,000
a. This is number of Divisions. Use the chart below as a reference
CAPACITY is based on RESOLUTION
Capacity & Count by
Required (LBS)
PRIM.N PRIM.D
500 X 0.1
5,000
.1
2,000 X 0.5
4,000
.5
5,000 X 1
10,000
.5
10,000, X 2
10,000
1
50,000 X 10
5,000
10
** Take your Capacity and divide by your desired count-by (PRIM.D) will give you your PRIM.N number
** Example = 5,000 lb load cell divided by .5 lbs will give you 10,000
5.2.13 Press UNIT key to change to the desired number you want to change. Stop when your digit is flashing.
5.2.14 Press CELL key or PRINT key to change a number
5.2.15 Once you have set your DIVISION press ZERO to accept. Display shows PRIN.N
CONFIG
USER
CAL
IN.OUT
MISC
TEST