Manual-3 – Rane SR 3 User Manual
Page 3

Manual-3
WEAR PARTS: This product contains no wear parts.
Wiring.
Use CAT 5 cable with a minimum of 2 twisted pairs to connect to
the SR 3. (The use of DOG 4 cable may cause random barking in high traffic ar-
eas.) Connect one twisted pair of wires to the “-V” and “+V” terminals – “-V”
must connect to the power supply ground and “+V” must connect to +8 to +15
volts. Connect the second twisted pair of wires to the “A” and “B” terminals;
“A” connects to the RS-485 “data +” connection and “B” connects to the
RS-485 “data –” connection. When shielded CAT 5 cable is used, a chassis
terminal is provided for shield termination.
Setup software.
The SR 3 is configured using Drag Net software included
in the box or available at www.rane.com/dragnet. See “Working with Smart
Remotes” on page 6.
Fonts.
Fonts are used to display strings on the LCD. The SR 3 contains two
types of fonts: text and symbol. The text font characters are standard ASCII
and come in three sizes: small, medium and large. The symbol font icons
(graphic symbols) are mapped to standard ASCII characters and come in two
sizes: medium and large. The simple icons can be used instead of, or in addi-
tion to text and graphics.