Manual-27 – Rane SR 3 User Manual
Page 27
Manual-27
IR
Input Raw
n1,n2,n3,n4,"OK"
IS
n1,n2
Input Suggest
n1,n2,"OK"
ISR
n1,n2
Input Suggest Raw
n1,n2,n3,n4,"OK"
IF
n1,n2
Input Force
"OK"
* [ ] denotes optional Command Argument
** Responses from concatenated commands produce only one "OK"
Configuration Commands
V
Get Firmware, Hardware Version
Send: V
Response: n1,n2,"OK"
Where: n1 is a two digit ASCII encoded decimal value
representation of the firmware version. The first digit is
the major firmware version and the second digit is the
minor
firmware
version.
n2 is a one digit ASCII encoded decimal value
representation of the hardware version.
Example: 13,2,"OK" means firmware version 1.3, hardware
version 2.
N
Read/Write Device's Name
The device’s name is limited to 32 characters and is stored in non-volatile memory.
The default name is SR 3.
To read the device’s name:
Send: N
Response: "ccc","OK"
Where: ccc is the device’s name.
Example: "SR 3","OK" means the device’s name is SR 3
To write a new name to the device:
Send: N,"ccc"
Where: ccc is the new name.
Example: N,"Conference Room 101" will rename the device to
Conference Room 101
Response: "OK"
SPL
Read/Write Stored Parameter
Various configuration parameters are stored in non-volatile memory. This command
reads and writes these parameters. For details of each parameter, see the Stored Pa-
rameter List
section following the Command Set section.