beautypg.com

Manual-27 – Rane SR 3 User Manual

Page 27

background image

Manual-27

IR

Input Raw

n1,n2,n3,n4,"OK"

IS

n1,n2

Input Suggest

n1,n2,"OK"

ISR

n1,n2

Input Suggest Raw

n1,n2,n3,n4,"OK"

IF

n1,n2

Input Force

"OK"

* [ ] denotes optional Command Argument

** Responses from concatenated commands produce only one "OK"

Configuration Commands

V
Get Firmware, Hardware Version

Send: V

Response: n1,n2,"OK"

Where: n1 is a two digit ASCII encoded decimal value

representation of the firmware version. The first digit is

the major firmware version and the second digit is the

minor

firmware

version.

n2 is a one digit ASCII encoded decimal value

representation of the hardware version.

Example: 13,2,"OK" means firmware version 1.3, hardware

version 2.

N
Read/Write Device's Name

The device’s name is limited to 32 characters and is stored in non-volatile memory.

The default name is SR 3.

To read the device’s name:

Send: N

Response: "ccc","OK"

Where: ccc is the device’s name.

Example: "SR 3","OK" means the device’s name is SR 3

To write a new name to the device:

Send: N,"ccc"

Where: ccc is the new name.

Example: N,"Conference Room 101" will rename the device to

Conference Room 101

Response: "OK"

SPL
Read/Write Stored Parameter

Various configuration parameters are stored in non-volatile memory. This command

reads and writes these parameters. For details of each parameter, see the Stored Pa-

rameter List

section following the Command Set section.