4 indicator operations, 1 toggle gross/net mode, 2 toggle units – Rice Lake IQ Plus 355 Installation Manual V1.17 User Manual
Page 7: 3 zero scale, 4 acquire tare, 5 remove stored tare value, 6 print ticket, Toggle gross/net mode, Toggle units, Zero scale

Introduction
3
Table 1-1 shows which annunciators are used for all combinations of configured primary and secondary units.
For example:
•
If the primary unit is pounds (lb) and the secondary unit is kilograms (kg), the
lb
LED is lit for primary
units,
kg
for secondary units.
•
If the primary unit is pounds (lb) and the secondary unit is short tons (tn), the
lb
LED is lit for primary
units,
kg
for secondary units. There is no LED for short tons, so the
kg
LED is used as the secondary units
annunciator.
•
If the primary unit is short tons (tn) and the secondary unit is pounds (lb), the
lb
LED is lit for primary
units (tn), and
kg
is lit for secondary units (lb). Because there is no LED for short tons, the
lb
and
kg
LEDs
are used as primary and secondary units annunciators.
See Section 3.2.2for more information about configuring primary and secondary display units.
1.4
Indicator Operations
Basic IQ plus 355 operations are summarized below.
1.4.1
Toggle Gross/Net Mode
Press the
GROSS/NET
key to switch the display mode
from gross to net, or from net to gross. If a tare value
has been entered or acquired, the net value is the gross
weight minus the tare.
Gross mode is shown by the
Gross
annunciator; net
mode is shown by the
Net
annunciator.
1.4.2
Toggle Units
Press the
UNITS
key to switch between primary and
secondary units. The units LED to the right of the
display is lit.
1.4.3
Zero Scale
1. In gross mode, remove all weight from the
scale and wait for the standstill annunciator
(
).
2. Press the
ZERO
key. The center of zero
(
) annunciator lights to indicate the
scale is zeroed.
1.4.4
Acquire Tare
1. Place container on scale and wait for the
standstill annunciator (
).
2. Press the
TARE
key to acquire the tare weight
of the container. The indicator switches to net
mode.
1.4.5
Remove Stored Tare Value
1. Remove all weight from the scale and wait for
the standstill annunciator (
).
2. Press the
TARE
key. The indicator switches to
gross mode, indicating the tare value has been
removed.
1.4.6
Print Ticket
1. Wait for the standstill annunciator (
).
2. Press the
key to send data to the serial
port.
Primary Unit
Secondary Unit
lb
kg
oz
g
tn
t
none
lb
lb / lb
lb / kg
lb / oz
lb / g
lb / kg
kg
kg / lb
kg / kg
kg / oz
kg / g
lb / kg
oz
oz / lb
oz / kg
oz / oz
oz / g
oz / kg
g
g / lb
g / kg
g / oz
g / g
g / kg
tn
lb / kg
lb / kg
lb / oz
lb / g
lb / lb
lb / kg
lb / kg
t
lb / kg
lb / lb
lb / kg
none
lb / kg
lb / kg
lb / lb
Table 1-1. Units Annunciators, Showing Primary / Secondary LEDs Used for All Configurations