Rice Lake IQ Plus 355 Installation Manual V1.17 User Manual
Page 37

EDP Commands
33
310 Command
355 Command
Description
AZ
KZERO
Sets scale to zero. Valid only in Operate Mode.
FT
KTARE
Performs a front panel tare operation. Entering “FT
the TARE key.
CT
Clear Tare
Tare out (removes the tare value)
LB
KPRIM
Selects “lb” for weight units (if set up for “lb” or “kg” units mode)
KG
KSEC
Selects “kg” for weight units (if set up for “lb” or Kg” units mode)
GN
KGROSSNET
Simulates a GROSS/NET key press. Entering “GN
and net display mode.
PR
KPRINT
Sends formatted weight data to either or both serial ports.
RS
RS
Resets system.
SX
SX
Starts continuous serial transmission on the EDP port using the selected serial output
data format. Serial transmission stops in SETUP mode.
EX
EX
Ends continuous serial transmision on the EDP port.
XG
XG
Transmits GROSS [9 characters, leading zeros suppressed (spaces), decimal point if
applicable, minus sign to left of first active digit]. Valid only in Operate Mode.
XN
XN
Transmits NET [9 characters, leading zeros suppressed (spaces), decimal point if
applicable, minus sign to left fo first active digit]. Valid only in Operate Mode.
XT
XT
Transmits TARE [9 characters, leading zeros suppressed (spaces), decimal point if
applicable, minus sign to left fo first active digit]. Valid only in Operate Mode.
XD
P command
Transmits the value currently displayed.
XS
S command
Transmits a single serial string from the EDP port in the selected output format.
Table 5-12 IQ310A Commands