12 rate count by, 13 totalizer count by, 14 load display units – Rice Lake BCi Belt Scale - Installation & Operation Manual Version 2.00 User Manual
Page 47: 15 load count by, 16 auto zero tracking (%), 17 auto zero tracking percentage, 18 dead band, T (metric tons) • lt (long ton) press the, Key on the integrator and a, Again to save that value

BCi
Installation & Operation Manual - Supervisor Mode Parameters
41
•
T (metric tons)
•
LT (long ton)
Press the
enter
key to toggle between the listed
choices above. The default rate display is TN/Hr.
4.12 Rate Count By
This parameter defines what county by and decimal
divisions the rate will be displayed. This is a value
that can be keyed in using the numeric keypad on the
display, 1, 2, 0.1, 0.01, etc. To change the rate count
by value, press the
enter
key on the integrator and a
rate count by prompt
appears. Using the numeric keypad
on the integrator, enter the value and press
enter
again
to save that value.
4.13 Totalizer Count By
This parameter is defined by what the count by and
decimal divisions the totalizers will be displayed. This
is a value that can be keyed in such as 1, 2, 0.1, 0.01,
erc. To change the totalizer count by value, press the
enter
key on the integrator and a
totalizer count by
prompt appears. Using the numeric keypad on the
integrator, enter the value and press
enter
again to save
that value.
4.14 Load Display Units
This parameter defines what weight units the belt
loading is displayed in. The selections are displayed in
the following units:
•
Lb - default
•
kg
Press the
enter
key to toggle between the listed
choices. The default load display unit is Lb.
4.15 Load Count By
This parameter is defined by what count by and
decimal divisions the load is to be displayed in. this is
a value that can be keyed in using the numeric keypad
on the BCi such as 1, 2, 0.1, 0.01, etc. To change the
load count by value, press the
enter
key on the
integrator and a
load count by
prompt appears. Using
the numeric keypad on the integrator, enter the value
and press
enter
again to save that value.
4.16 Auto Zero Tracking (%)
This is the percentage of full scale that zero tracking is
attempted. If the rate is larger than this value, the zero
tracking is turned off.
4.17 Auto Zero Tracking Percentage
This is the percentage of full scale that will zero a
track off.
4.18 Dead Band
The accumulator will only totalize the amount if the
rate is above the dead band value. Press the
enter
key
to add the dead band value and press
enter
again to
save that value.
End
SCALE #1
Home
Cancel
11/23/2011
08:13AM
Load Cell MV
Total LC Build
Rate Unit Time
Filter
Speed Unit Time
Fixed Speed
Unit of Measure
Unit of Rate
Rate Count By
Totalizer Count By
200.00
Min
10
Min
5.0
Ft
T
0.1
0.1
2.0000
Rate Count By
End
SCALE #1
Home
Cancel
11/23/2011
08:13AM
Load Cell MV
Total LC Build
Rate Unit Time
Filter
Speed Unit Time
Fixed Speed
Unit of Measure
Unit of Rate
Rate Count By
Totalizer Count By
200.00
Min
10
Min
5.0
Ft
T
0.1
0.1
2.0000
Totalizer Count By
End
SCALE #1
Home
Cancel
11/23/2011
08:13AM
Load Display Units
Load Count By
Auto Zero Tracking
Filter
Speed Unit Time
Fixed Speed
Unit of Measure
Unit of Rate
Rate Count By
Totalizer Count By
Lb
0.1
10
Min
5.0
Ft
T
0.1
0.1
0.1
Load Count By