Rice Lake 480 Legend Series Digital Weight Indicator Installation Manual User Manual
Page 57

Appendix 53
Figure 9-3. STR-4: Cardinal Indicator Format
Figure 9-4. STR-2: Toledo Indicator Format
Demand Output Serial Data Format
The 480 uses a data string formatted in the print format parameters (depending on mode) for ticket printout. The
particular ticket format printed depends on the indicator configuration.
You can customize the ticket to work with a wide variety of printers, scoreboard displays, and other remote
equipment. See Section 7.0 for more information on custom print formats.
DEVMOD should be set to NONE to use demand output on port 2.
DEVMOD should be set to LOCAL to enable port 2 streaming.
Port 1 cannot be set to stream.
Carriage
Return
Polarity:
<+> for positive
"–" for negative
Six digits, right justified, floating decimal
(follows weight if not embeded),
leading zeroes are present.
g for Gross
n for Net
Hex value of <03>
is entered in string
lb = pound
kg = kilogram
g = gram
tn = ton (short)
t = ton (metric)
gr = grain
oz = ounce
Space
Character
Space character
(2)
Space
Character
Status:
m = motion
o = over/under range
STX (02h)
Status Word A
of string.
Status Word B
Status Word C
7
6
5
4
3
2
1
0
0
1
MUL1 MUL0
DP2
DP1
DP0
Parity
DP2 DP1 DP0 Fixed Zero/Dec. Pt. Location
0 0 0 x 100
(2 fixed zeroes)
0 0 1 x 10
(1 fixed zero)
0 1 0 x 1
(No decimal point)
0 1 1 x 0.1
(1 decimal place)
1 0 0 x 0.01
(2 decimal places)
1 0 1 x 0.001
(3 decimal places)
1 1 0 x 0.0001
(4 decimal places)
1 1 1 x 0.00001 (5 decimal places)
Disp. Div.
MUL1 MUL0 Multiplier
0 1 x 1
1 0 x 2
1 1 x 5
Even parity bit.
Requires EDP Port setup.
Status Word A:
7
6
5
4
3
2
1
0
0
1
Status Word C: ASCII 20h (space)
0
0
0
0
0
Even parity bit:
Requires EDP Port setup.
Parity
Status Word B:
7
6
5
4
3
2
1
0
0
1
0 = Gross Display Mode
1 = Net Display Mode
0 = Positive indicated weight value
1 = Negative indicated weight valu
e
0 = In range
1 = Out of range
0 = Stable
1 = Motion
0 = lb
1 = kg
Even parity bit:
Requires EDP Port
setup.
Parity
Six digits, right justified, dummy zeros, decimal
point with no leading zeroes except for immediately
preceding the decimal point. Leading zeroes
transmitted as spaces.
Tare Weight: Six digits, right justified, dummy zeros,
decimal point with no leading zeroes except for
immediately preceding the decimal point.
Leading zeroes transmitted as spaces.
Note