480 Operator’s Manual
PROGRM Menu
Parameter
Choices
Description
Program submenus
PWRUPM
GO
DELAY
Power up mode. In GO mode, the indicator goes into operation immediately after a brief power
up display test.
In DELAY mode, the indicator performs a power up display test and then enters a 30 second
warm-up period. If no motion is detected during the warm-up period, the indicator becomes
operational when the warm-up period ends; if motion is detected, the delay timer is reset and
the warm-up period repeated.
REGULA
NTEP
OIML
CANADA
NONE
Regulatory mode. Specifies the regulatory agency having jurisdiction over the scale site.
OIML, NTEP, and CANADA modes allow a tare to be acquired at any weight greater than zero.
NONE allows tares to be acquired at any weight value.
OIML, NTEP, and CANADA modes allow a tare to be cleared only if the gross weight is at no
load. NONE allows tares to be cleared at any weight value.
NTEP and OIML modes allow a new tare to be acquired even if a tare is already present. In
CANADA mode, the previous tare must be cleared before a new tare can be acquired.
NONE, NTEP and CANADA modes allow the scale to be zeroed in either gross or net mode as
long as the current weight is within the specified ZRANGE. In OIML mode, the scale must be in
gross mode before it can be zeroed; pressing the ZERO key in net mode clears the tare.
CONSNU
000000
0 – 999999
Consecutive numbering. Allows sequential numbering for print operations. The consecutive
number value will increment following each print operation. This value is read only.
The initial value of this parameter is set to the start up value specified on the
CONSTU parameter. Changing CONSTU immediately resets the consecutive
number used for printing.
CONSTU
000000
0 – 999999
Consecutive number start up value. Specifies the initial consecutive number (CONSNU) value
used when the indicator is reset or configured.
Consecutive numbering starts with number entered.
Example: If 100 is entered the first ticketed printed will be 100.
ACCUM
OFF
ON
Turns the accumulator on and off. Stores the accumulated weight, time and date of last
accumulation.
RTZGRD
0
0 – 999999
Return to zero grads to re-arm the accumulator. Default = 0.
DATE
DATFMT
DATSEP
Allows selection of date format and date separator. See below for parameter descriptions.
DATE submenus
DATFMT
MMDDYY
DDMMYY
YYMMDD
YYDDMM
Specifies the format used to display or print the date.
DATSEP
SLASH
DASH
SEMI
Specifies the date separator character.
Program submenu
TIME
TIMFMT
TIMSEP
Allows selection of time format and separator. See below for parameter descriptions.
TIME submenus
TIMFMT
24HOUR
12HOUR
Specifies the format used to display or print the time.
TIMSEP
COLON
COMMA
Specifies the time separator character.
Table 3-10. Program Menu Parameters