0 configuration, 1 front panel navigation, Configuration – Rice Lake 480 Legend Series Digital Weight Indicator Installation Manual User Manual
Page 22: E section 3.1

18
480 Operator’s Manual
3.0 Configuration
There are two types of configuration parameters in the 480. Legal for Trade configuration and non-legal
configuration (or operator parameters). Legal for Trade configuration requires pressing the setup switch (see
Section 3.3). Non-legal configuration parameters do not require pressing the setup switch, but may be password
protected.
The following sections provide graphic representations of the 480 menu structures. In the actual menu structure,
the settings you choose under each parameter are arranged horizontally. To save page space, menu choices are
shown in vertical columns. The factory default setting appears at the top of each column in bold type. Most menu
diagrams are accompanied by a table that describes all parameters and parameter values associated with that menu.
Parameter level is indicated by the left LED position, levels 1-4.
3.1 Front Panel Navigation
Figure 3-1. Front Panel Key Functions
Four front panel keys are used as directional keys to navigate through the menus (see Figure 3-1).
•
UNIT
( ) and
( ) scroll left and right on the same menu level.
•
ZERO
( ) and
GROSS/NET
( ) move up and down to different menu levels.
• The
TARE
key serves as an Enter key (
) for selecting parameter values within the menus.
• The
MENU
key allows front panel access to user setup and configuration mode.
Figure 3-2. Menu Navigation
To select a parameter, press or to scroll left or right until the desired menu group appears on the display, then
press to move down to the submenu or parameter you want. When moving through the menu parameters, the
present value appears first on the display.
To change a parameter value, scroll left or right to view the values for that parameter. When the desired value
appears on the display, press
ENTER
(
TARE
) to select the value and move back up one level. To edit numerical
values, use the navigation keys to select the digit and to increment or decrement the value.
Figure 3-3. Editing Procedure for Numeric Values
Note
MENU
UNIT
POWER
TARE
GROSS
NET
B/N
ZERO
Move RIGHT/Next
Move UP/Increment Value
Access User Setup
ENTER Value
Move LEFT/Previous
Move DOWN/Decrement Value
Power ON/OFF
1
st
Level
Parameter
Preset Value
Value
When moving through values below the first menu level, press
to return to the level
above. Press
to move to the next parameter on the level below.
2
nd
Level
Parameter
Value
Value
1
st
Level
Parameter
2
nd
Level
Parameter
0
0 0 0 0 0
When editing numeric values, press or to change the
digit selected. Press or to increment or decrement the
value of the selected digit. Press to save the value entered
and return to the level above.