5 normal mode commands, Normal mode commands, Gh 5-12 for more information – Rice Lake Intrinsically Safe User Manual
Page 47

320IS Installation Manual - EDP Commands
41
5.1.5
Normal Mode Commands
The serial transmit weight data commands (see Table 5-13) transmit data to the EDP port on demand. The SX and
EX commands are valid only in normal operating mode; all other commands are valid in either setup or normal
mode.
Command
Description
Values
AO2.SOURCE
Analog output source
GROSS, NET
AO2.OFFSET
Zero offset
0%, 20%
AO2.ERRACT
Error action
FULLSC, HOLD, ZEROSC
AO2.MIN
Minimum value tracked
0–999 990
AO2.MAX
Maximum value tracked
0–999 990
AO2.TWZERO
Zero calibration
0–65535
AO2.TWSPAN
Span calibration
0–65535
Table 5-12. ALGOUT 2 EDP Commands
Command
Description
Response Format
SX
Start EDP streaming
OK or ??
EX
Stop EDP streaming
OK or ??
RS
Reset system
—
XG
Transmit gross weight in displayed units
nnnnnn UU
where nnnnnn is the weight value, UU is the units.
XN
Transmit net weight in displayed units
XT
Transmit tare weight in displayed units
XG2
Transmit gross weight in non-displayed units
XN2
Transmit net weight in non-displayed units
XT2
Transmit tare weight in non-displayed units
XE
Query system error conditions
xxxxx yyyyy
See Section 7.1.2 on page 46 for detailed information about
the XE command response format.
XA
Transmit accumulation value
UID
set unit ID
nnnnnn
CONSNUM
Set consecutive number
Table 5-13. Normal Mode EDP Commands