beautypg.com

4 appendix d error messages, Table 8-15. error messages, 5 appendix e front panel display characters – Rice Lake 120 Plus Digital Weight Indicator User Manual

Page 49: Figure 8-4. 120 plus display characters

background image

Appendix

45

8.4

Appendix D Error Messages

The 120 Plus indicator displays a number of error messages. When an error occurs, the message is shown on the
indicator LED display.

8.5

Appendix E Front Panel Display Characters

Figure 8-4. 120 Plus Display Characters

Error Message

Description

Solution

EMPTY SCREEN

Gross > Overload limit

Gross value exceeds overload limit. Check configuration or
signal input level.

UNDER DASHES

Underflow error

Weight value too small to be displayed

OVER DASHES

Overflow error

Weight value too large to be displayed

AD LOW

A/D over negative range

Check scale for binding or damage

AD HI

A/D over positive range

Check scale for binding or damage

EE SUM

Parameter or calibration check- sum error

Recalibration is needed; contact Rice Lake Weighing Systems
service

WW WR

EEPROM write error

Contact Rice Lake Weighing Systems service

PM SUM

Internal program checksum error

Contact Rice Lake Weighing systems service

HOFSET

Load > calibrated zero + capacity x INIZR

Check weight and INIZR

LOFSET

Load < calibrated zero + capacity x INIZR

Check weight and INIZR

UOFSET

Unstable within 2 sec of powering on

Check weight and INIZR

Table 8-15. Error Messages

%

&

(

)

*

/