Configuration
17
Parameter
Options
Description
Primary
DECPNT
DSPDIV
UNIT
Specifies the Primary decimal position, display divisions, and units
used for the primary units.
Decimal point
888888
8.88888
88.8888
888.888
8888.88
88888.8
Decimal Point defines the location of the decimal point or dummy zero
for the primary unit display. The value set should be consistent with
local legal requirements.
Display divisions
1D
2D
5D
10D
20D
50D
Display Division defines the minimum division size for the weight
displayed by the primary units.
Units
LB (pound)
KG (kilogram)
OZ (ounce)
G (gram)
T (ton)
This defines the primary Units for display and printing.
Secondary
DECPNT
DSPDIV
UNIT
Specifies the Secondary decimal position, display divisions, and units
used for the secondary units.
Decimal point
88888.8
888888
8.88888
88.8888
888.888
8888.88
Decimal Point Location defines the location of the decimal point or
dummy zero for the primary unit display. The value set should
be consistent with local legal requirements.
Display divisions
5D
1D
2D
10D
20D
50D
Display Divisions defines the minimum division size for the weight
displayed by the secondary units.
Units
KG (kilogram)
G (gram)
OZ (ounce)
T (ton)
LB (pound)
This defines the secondary Units for display and printing.
Display rates
250 MS
500 MS
1 Sec
2 Sec
Display Rate - sets the update rate for displayed values.
Hires
OFF
ON
Hires - sets ON the instrument to display weight at 10 times resolution.
This is intended for test purposes but may be used for non-trade
weighing.
Note: Do not set this parameter to ON if PRI. DECPNT = 8.88888 or
SEC. DECPNT = 8.88888.
On high resolution mode the display blinks.
Table 3-3. Format Menu