9 other commands, Table 8-9. other commands, 10 key press on edp commands – Rice Lake 120 Plus Digital Weight Indicator User Manual
Page 44: Table 8-10. key press commands, 11 tare, zero key and regulat parameter, Zero or negative, No active, Zero, Clear tare, Positive

40
120Plus Digital Weight Indicator Technical Manual
8.1.9
Other Commands
8.1.10 Key Press on EDP Commands
8.1.11 Tare, Zero key and REGULAT Parameter
The function of the
TARE
and
ZERO
keys depends on the value specified for the
REGULAT
parameter. Table 8-11
below describes the function of these keys for each of the regulatory modes.
Command
Description
Values
DEFAULT
Reset default parameter values
-
RS
Software Reset
IO
Report status 4 ports IO and set point I3, I2, I1, O3, O2, O1
Table 8-9. Other Commands
Command
Description
Values
KZERO
Same function as ZERO key press
-
KGROSSNET
Same function as GROSS/NET key press
-
KTARE
Same function as TARE key press
-
KUNITS
Same function as UNITS key press
-
KPRIUNIT
Force to primary unit
-
KSECUNIT
Force to secondary unit
-
KPRINT
Same function as PRINT key press
-
KHOLD
Same function as HOLD key press
KENTER
Same function as ENTER key press
KPTARE
Same function as PRESET TARE key press
KCLEAR
Same function as CLEAR key press
KNR0-9
Same function as 0-9 key press
Table 8-10. Key Press Commands
REGULAT
parameter value
Weight on scale
Tare in system
Key press function
KTARE
KZERO
USA
zero or negative
no
no active
zero
yes
clear tare
positive
no
tare
yes
tare
CANADA
zero or negative
no
no active
zero
yes
clear tare
positive
no
tare
yes
no active
EUROPE
zero or negative
no
no active
zero
yes
clear tare
zero and clear tare
positive
no
tare
zero
yes
tare
zero and clear tare
NONE
zero or negative
no
tare
zero
yes
clear tare
positive
no
tare
yes
clear tare
Table 8-11. Regular Parameter Values