Kontron NSC2U IP Network Server User Manual
Page 115

Kontron IP Network Server NSC2U
December 2009
Product Guide, rev. 1.4
115
2. Remove the chassis cover, the front panel bezel, and the processor air duct. For
instructions, see see
,
.
3. Remove the drive bay assembly. For instructions, see
Drive Bay Assembly” on page 111
4. Remove the power supply module(s). For instructions, see
“Replacing a Power Supply” on page 31
.
5. Remove the PCI riser card assembly. For instructions, see
the PCI Riser Card Assembly” on page 53
.
6. Remove the PCI fan assembly. For instructions, see
.
7. Remove the CPU fan assembly. For instructions, see
.
8. Disconnect the cable harnesses at the other ends on the T5000PAL server board
and the SFP board.
9. Press down on the metal clip at the base of the PDB assembly to free the PDB
assembly. (
, “A”)
10. Gently pull the PDB assembly off of the placement pegs. (“B”).
11. Lift the PDB from the chassis (“C”).
5.5.2
Installing the Power Distribution Board Back into the Chassis
1. Lower the replacement power distribution board (PDB) into place. (
, “A”)
2. Make sure that the PDB is placed over the placement pegs and gently push down.
(“B”)
Figure 101. Removing the PDB
TS000568
A
B
C