Kontron NSC2U IP Network Server User Manual
Page 108

NSC2U Server—5
Kontron IP Network Server NSC2U
Product Guide, rev. 1.4
December 2009
108
3. Remove the PCI fan assembly, including the flex cable that covers it. For
Section 5.2.4, “Replacing the PCI Fans in the Fan Shroud” on
4. Remove the CPU fan assembly. For instructions, see
5. Disconnect all of the cables connected to the SFP board:
— SAS backplane power cable
— All four fan power cables
— Two power input cables from the power distribution board
— Flex cable
— RAID IBBU cable, if installed
— Front serial port cable
Section 33, “NSC2U Server System Cable Routing” on page 51
as a reference
for all of the connectors.
6. Remove the bridge board by opening the connector latch (
, “A”) and lifting
the board up from both ends. (“B”)
Figure 94.
Removing the Bridge Board
TS000565
A
B