Installing the fan assembly back into the chassis, Section 5.2.5, “installing the fan assembly back – Kontron NSC2U IP Network Server User Manual
Page 106

NSC2U Server—5
Kontron IP Network Server NSC2U
Product Guide, rev. 1.4
December 2009
106
5.2.5
Installing the Fan Assembly Back into the Chassis
1. Place the fan assembly back into the chassis. (
, “A”)
2. Plug the PCI fan power cables into the connectors on the SFP board. (“B”)
3. Run the cable back over the PCI fan assembly. (
, “A”)
4. Reconnect the flex cable to the SAS backplane board. (“B”)
5. Re-install the flex cable support bracket.
6. If this is the last task you are performing, replace the top cover of the chassis.
Reconnect all the external devices and plug in the power cord(s).
For information about mounting the server in a rack, see
the Server into a Rack” on page 48
Figure 92.
Installing the PCI Fan Assembly into the Chassis
TS000563
A
B