Dell PowerEdge M820 (for PE VRTX) User Manual
Page 90

Error Code
Message Information
Details
The <name> battery is either missing, bad, or unable to
charge due to thermal issues.
Action
Check system fans. Replace the <name> battery.
BAT0019
Message
The <name> battery is absent.
LCD Message
The <name> battery is absent. Check battery.
Details
The failed or missing <name> battery may reduce system
performance.
Action
Check system fans. Replace the <name> battery.
CBL0006
Message
Multiple storage controllers are incorrectly connected to the
same backplane <Bay ID>.
Details
Unsupported backplane configuration.
Action
Check backplane configuration. Reconnect cable. If the issue
persists, see
CPU0000
Message
CPU <number> has an internal error (IERR).
LCD Message
CPU <number> has an internal error (IERR).
Details
System event log and OS logs may indicate that the
exception is external to the processor.
Action
Review System Event Log and Operating System Logs. If the
issue persists, see
.
CPU0001
Message
CPU <number> has a thermal trip (over-temperature) event.
LCD Message
CPU <number> has a thermal trip. Check CPU heat sink.
Details
The processor temperature increased beyond the
operational range.
Action
Review logs for fan failures, replace failed fans. If no fan
failures are detected, check inlet temperature (if available)
and reinstall processor heat-sink.
CPU0002
Message
CPU <number> has failed the built-in self-test (BIST).
Action
1.
Turn system off and remove input power for one
minute. Reapply input power and turn system on.
2.
Make sure the processor is seated correctly.
3.
90