Error Code
Message Information
Action
Review System Log or front panel for additional information.
LNK2700
Message
The <name> LAN heartbeat is lost.
Details
CMC has lost network connection.
Action
Check network cable and network connections.
MEM0000
Message
Persistent correctable memory errors detected on a memory
device at location(s) <location>.
Details
This is an early indicator of a possible future uncorrectable
error.
Action
Re-seat the memory modules. If the issue persists, see
.
MEM0001
Message
Multi-bit memory errors detected on a memory device at
location(s) <location>.
LCD Message
Multi-bit memory error on <location>. Re-seat memory.
Details
The memory module has encountered a uncorrectable error.
System performance may be degraded. The operating
system and/or applications may fail as a result.
Action
Re-seat the memory modules. If the issue persists, see
.
MEM0002
Message
Parity memory errors detected on a memory device at
location <location>.
Details
The memory is operational. This an early indicator of a
possible future uncorrectable error.
Action
Re-seat the memory modules. If the issue persists, see
.
MEM0003
Message
Stuck bit memory error detected on a memory device at
location <location>.
Details
This is an early indicator of a possible future uncorrectable
error.
Action
Re-seat the memory modules. If the issue persists, see
.
MEM0004
Message
Memory device at location <location> is disabled.
104