Error Code
Message Information
Details
Chassis power level current is outside of the optimum range.
Action
1.
Review system power policy.
2.
Check system logs for power related failures.
3.
Review system configuration changes.
4.
ASR0000
Message
The watchdog timer expired.
Details
The operating system or an application failed to
communicate within the time-out period.
Action
Check the operating system, application, hardware, and
system event log for exception events.
ASR0001
Message
The watchdog timer reset the system.
Details
The operating system or an application failed to
communicate within the time-out period. The system was
reset.
Action
Check the operating system, application, hardware, and
system event log for exception events.
ASR0002
Message
The watchdog timer powered off the system.
Details
The operating system or an application failed to
communicate within the time-out period. The system was
shut down.
Action
Check the operating system, application, hardware, and
system event log for exception events.
ASR0003
Message
The watchdog timer power cycled the system.
Details
The operating system or an application failed to
communicate within the time-out period. The system was
power-cycled.
Action
Check the operating system, application, hardware, and
system event log for exception events.
ASR0008
Message
The watchdog timer interrupt was initiated.
Details
The operating system or an application failed to
communicate within the time-out period. No action was
taken.
86