Error Code
Message Information
ASR0105
Message
The operating system watchdog timer powered off the
system.
Details
The operating system or an application failed to
communicate within the time-out period. The system was
powered off.
Action
Check the operating system, application, hardware, and
system event log for exception events.
ASR0106
Message
The watchdog timer expired.
Details
The operating system or an application failed to
communicate within the time-out period.
Action
Check the operating system, application, hardware, and
system event log for exception events.
ASR0107
Message
The watchdog timer pre-timeout interrupt was initiated.
Details
The operating system or an application failed to
communicate within the time-out period.
Action
Check the operating system, application, hardware, and
system event log for exception events.
BAT0000
Message
The system board battery is low.
Details
The system board battery is either missing, bad, or unable to
charge due to thermal issues.
Action
Check system fans. Replace the system board battery.
BAT0002
Message
The system board battery has failed.
LCD Message
The system board battery has failed. Check battery.
Details
The system board battery is either missing or bad.
Action
BAT0004
Message
The system board battery is absent.
LCD Message
The system board battery is absent. Check battery.
Action
Reinstall the system board battery.
BAT0005
Message
The storage battery is low.
Details
System has to remain powered on to charge the battery.