Dell PowerEdge M820 (for PE VRTX) User Manual
Page 146

Error Code
Message Information
Action
1.
Review system logs for power supply exceptions.
2.
Re-configure the system to minimum configuration,
inspect and reinstall system cables.
3.
VLT0210
Message
The memory module <number> <name> voltage is outside
of range.
LCD Message
Memory module <number> <name> voltage is outside of
range.
Details
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.
Action
1.
Review system logs for power supply exceptions.
2.
Re-configure the system to minimum configuration,
inspect and reinstall system cables.
3.
VLT0212
Message
The disk drive bay <name> voltage is less than the lower
warning threshold.
LCD Message
The disk drive bay <name> voltage is outside of range.
Details
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.
Action
1.
Review system logs for power supply exceptions.
2.
Re-configure the system to minimum configuration,
inspect and reinstall system cables.
3.
VLT0213
Message
The disk drive bay <name> voltage is less than the lower
critical threshold.
LCD Message
The disk drive bay <name> voltage is outside of range.
Details
System hardware detected an over voltage or under voltage
condition.
146