Dell PowerEdge M820 (for PE VRTX) User Manual
Page 143

Error Code
Message Information
VLT0200
Message
The system board <name> voltage is less than the lower
critical threshold.
LCD Message
System board voltage is outside of range.
Details
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.
Action
1.
Review system logs for power supply exceptions.
2.
Remove the processor module. Inspect processor
socket for bent pins.
3.
VLT0201
Message
The system board <name> voltage is less than the lower
warning threshold.
LCD Message
System board voltage is outside of range.
Details
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.
Action
1.
Review system logs for power supply exceptions.
2.
Re-configure the system to minimum configuration,
inspect and reinstall system cables.
3.
VLT0202
Message
The system board <name> voltage is greater than the upper
warning threshold.
LCD Message
System board voltage is outside of range.
Details
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.
Action
1.
Review system logs for power supply exceptions.
2.
Re-configure the system to minimum configuration,
inspect and reinstall system cables.
3.
143