Dell PowerEdge M820 (for PE VRTX) User Manual
Page 107

Error Code
Message Information
MEM1016
Message
Memory device at location <location> is not installed
correctly.
LCD Message
Memory <location> is not installed correctly. Reinstall.
Details
The memory may not be seated correctly, misconfigured, or
has failed. Memory size is reduced.
Action
Check the memory configuration. Re-seat the memory
modules. If the issue persists, see
MEM1205
Message
Memory mirror redundancy is lost. Check memory device at
location(s) <location>.
LCD Message
Memory mirror lost on <location>. Power cycle system.
Details
The memory may not be seated correctly, misconfigured, or
has failed.
Action
Check the memory configuration. Re-seat the memory
modules. If the issue persists, see
MEM1206
Message
Memory mirror redundancy is degraded. Check memory
device at location <location>.
Details
The memory may not be seated correctly, misconfigured, or
has failed.
Action
Check the memory configuration. Re-seat the memory
modules. If the issue persists, see
MEM1208
Message
Memory spare redundancy is lost. Check memory device at
location <location>.
LCD Message
Memory spare lost on <location>. Power cycle system.
Details
Memory sparing is no longer available.
Action
Re-seat the memory modules. If the issue persists, see
.
MEM1212
Message
Memory redundancy is lost.
Details
The memory may not be seated correctly, misconfigured, or
has failed.
Action
Review system logs for memory exceptions. reinstall
memory at location <location>
MEM1214
Message
Memory redundancy is degraded.
107