Dell PowerEdge M820 (for PE VRTX) User Manual
Page 105

Error Code
Message Information
Details
The memory may not be seated correctly, misconfigured, or
has failed. Memory size is reduced.
Action
Re-seat the memory modules. If the issue persists, see
.
MEM0005
Message
Persistent correctable memory error limit reached for a
memory device at location(s) <location>.
LCD Message
Persistent correctable memory error limit reached for
<location>. Re-seat memory.
Details
The memory is operational. This an early indicator of a
possible future uncorrectable error.
Action
Re-seat the memory modules. If the issue persists, see
.
MEM0007
Message
Unsupported memory configuration; check memory device
at location <location>.
LCD Message
Unsupported memory configuration. Check memory
<location>.
Details
The memory may not be seated correctly, misconfigured, or
has failed. Memory size is reduced.
Action
Check the memory configuration. Re-seat the memory
modules. If the issue persists, see
MEM0009
Message
Memory device at location <location> is throttled.
Details
System performance is degraded.
Action
If unexpected, review system logs for power or thermal
exceptions.
MEM0010
Message
Memory device at location <location> is over heating.
LCD Message
Memory device <location> is over heating. Check fans.
Details
System performance is degraded.
Action
If unexpected, review system logs for power or thermal
exceptions.
MEM0022
Message
Memory device at location <location> is absent.
Details
The memory may not be seated correctly, misconfigured, or
has failed. Memory size is reduced.
105