beautypg.com

Dell DR4000 User Manual

Page 23

background image

About Your System

23

Alert! iDRAC6 not
responding.
Rebooting.

The iDRAC6 is not

responding to BIOS

communication either

because it is not functioning

properly or has not

completed initialization.

The system reboots.

Wait for the system

to reboot.

Alert! iDRAC6 not
responding.
Power required
may exceed PSU
wattage.
Alert!
Continuing
system boot
accepts the risk
that system may
power down
without warning.

The iDRAC6 stops

responding.
The iDRAC6 was remotely

reset while system was

booting.
After AC recovery, the

iDRAC6 takes longer than

normal to boot.

Remove AC power to the

system for 10 seconds and

restart the system.

Alert! Node
Interleaving
disabled! Memory
configuration
does not support
Node
Interleaving.

The memory configuration

does not support node

interleaving, or the

configuration has changed

(for example, a memory

module has failed) so that

node interleaving cannot be

supported. The system still

runs, but without node

interleaving.

Ensure that the memory

modules are installed in a

configuration that supports

node interleaving.

Check other system

messages for additional

information for possible

causes. For memory

configuration information,

see "General Memory

Module

Installation Guidelines" on

page 76. If the problem

persists,

see "Troubleshooting System

Memory" on page 129.

Message

Causes

Corrective Actions

book.book Page 23 Friday, January 6, 2012 2:11 PM