Lan configuration, Power throttling configuration, Ip address – Dell PowerEdge C6100 User Manual
Page 50
50
Using the System Setup Program
LAN Configuration
Power Throttling Configuration
NOTE:
The default values are dependant on BMC setting
IP Address
Clear BMC System Event Log Clears BMC System Event Log.
BMC PEF status
Displays BMC PEF status.
Set BMC NIC
(Shared default)
Sets the type of BMC NIC from BIOS. BMC is reset.
Set LAN Configuration
Allows LAN Configuration settings.
Option
Description
Channel Number
(01 default)
Enters channel number for SET LAN Config
Command. Proper value is below 16.
BMC IP address source
(DHCP default)
Sets BMC IP address source from BIOS.
Option
Description
Power Throttling
Enable or disable Power throttling
Power CAP
Enable or disable Power CAP
Chassis CAP
Set Chassis CAP value
Option
Description
IP Address (default value
depends on BMC setting)
Enters IP address in decimal in the form of
XXX.XXX.XXX.XXX (XXX is less than 256 and in
decimal only).
NOTE:
When BMC IP status is static, IP Address is
useful
Option
Description
book.book Page 50 Thursday, March 4, 2010 4:38 PM