beautypg.com

Dell PowerEdge C6100 User Manual

Page 27

background image

About Your System

27

0086h

Yes

ATAPI 6 Error

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists, see
"Getting Help" on page 143.

0087h

Yes

ATAPI 7 Error

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists, see
"Getting Help" on page 143.

0120h

Yes

CPU1 Thermal Failure due to
PROCHOT#

Ensure that the processor
heat sinks are properly
installed.

See "Troubleshooting
Processors" on page 126 and
"Troubleshooting System
Cooling Problems" on
page 120.

0121h

Yes

CPU2 Thermal Failure due to
PROCHOT#

Ensure that the processor
heat sinks are properly
installed.

See "Troubleshooting
Processors" on page 126 and
"Troubleshooting System
Cooling Problems" on
page 120.

0122h

Yes

CPU3 Thermal Failure due to
PROCHOT#

Ensure that the processor
heat sinks are properly
installed.

See "Troubleshooting
Processors" on page 126 and
"Troubleshooting System
Cooling Problems" on
page 120.

Code

Log in BMC Cause

Corrective Actions

book.book Page 27 Thursday, March 4, 2010 4:38 PM