beautypg.com

System internal diagnostics view, Options, Example – Dell PowerVault NX3600 User Manual

Page 134: Description, Format, Arguments, Output

background image

Options

Option

Description

Format

-EnableDataReduction

Indicate whether data reduction
is enabled

Possible values are Yes, No

-StartingHour

Starting time of the data
reduction background process

Zero-based, whole positive
number (0 to 23)

-Duration

Number of hours that the data
reduction background process
will run

Whole positive number (1 to 24)

Example

Enable data reduction to start at 23:00:00 and run for 6 hours:
CLI> system internal file-system background-processes configuration data-

reduction set -EnableDataReduction Yes -StartingHour 23 -Duration 6

system internal diagnostics view

Description

View details about a single diagnostic.

Format

system internal diagnostics view

Arguments

Argument

Description

Format

Name of the diagnostic

Possible values are
ClientConnectivity,
FileAccessibility, FileSystemCore,
General, Network, Performance,
CIFSAndNFS

Example

View details about the Network diagnostic:
CLI> system internal diagnostics view Network

Output

Diagnostic Name = Network

Status = DiagIdle

Last Run = 11-May-13 12:33:33

File Name General Diagnostic = Summary.90fb2eb6-d44d-4440-abd8-adba59cb1101.

11_05_2013-12_33_06.tar.gz

134