Technical data – Baumer NE131 User Manual
Page 13

NE131
NE131
www.baumer.com
13
English
Technical data
Technical data - electrical ratings
Voltage supply
85...265 VAC (50/60 Hz), 10...30 VAC/VDC
Power consumption
1.5 VA, 2 W
Display
LCD, 7-segment, 2-lines, backlit
Number of digits
6-digits
Digit height
7 mm (count), 4 mm (preset)
Function
Preset counter
Scaling factor
0.0001...9999.99
Count mode
Adding or subtracting
Counting frequency
25 Hz (DC trigger: 1 kHz)
Data memory
>10 years in EEPROM
Reset
Button, electric or automatic
Keylock
Yes, electric (keylock)
Outputs relay
Potential-free changeover contact
Output holding time
0.01...99.99 s
Standard DIN EN 61010-1
Protection class II, Overvoltage category II
Pollution degree 2
Emitted interference
DIN EN 61000-6-3
Interference immunity DIN EN 61000-6-2
Programmable parameters
Measuring units, sensor logic,
decimal point, scaling factor, count mode
Approvals
UL approvals / E63076, CE conform
Technical data - mechanical design
Ambient temperature 0...+50 ºC
Storing temperature
-20...+70 ºC
Relative humidity
80 % non-condensing
E-connection
Plug-in screw terminals
Core cross-section
1.5 mm
2
Protection DIN EN 60529
IP 65 face with seal
Operation / keypad
Membrane with softkeys
Housing type
Built-in housing
Dimensions W x H x L 48 x 48 x 108 mm
Installation depth
108 mm
Mounting
Clip frame
Cutout dimensions
45 x 45 mm (+0.6)
Materials
Housing: Makrolon 6485 (PC)
Keypad: Polyester
Weight approx.
140 g