beautypg.com

Technical data – Baumer NE131 User Manual

Page 13

background image

NE131

NE131

www.baumer.com

13

English

Technical data

Technical data - electrical ratings

Voltage supply

85...265 VAC (50/60 Hz), 10...30 VAC/VDC

Power consumption

1.5 VA, 2 W

Display

LCD, 7-segment, 2-lines, backlit

Number of digits

6-digits

Digit height

7 mm (count), 4 mm (preset)

Function

Preset counter

Scaling factor

0.0001...9999.99

Count mode

Adding or subtracting

Counting frequency

25 Hz (DC trigger: 1 kHz)

Data memory

>10 years in EEPROM

Reset

Button, electric or automatic

Keylock

Yes, electric (keylock)

Outputs relay

Potential-free changeover contact

Output holding time

0.01...99.99 s

Standard DIN EN 61010-1

Protection class II, Overvoltage category II

Pollution degree 2

Emitted interference

DIN EN 61000-6-3

Interference immunity DIN EN 61000-6-2

Programmable parameters

Measuring units, sensor logic,

decimal point, scaling factor, count mode

Approvals

UL approvals / E63076, CE conform

Technical data - mechanical design

Ambient temperature 0...+50 ºC

Storing temperature

-20...+70 ºC

Relative humidity

80 % non-condensing

E-connection

Plug-in screw terminals

Core cross-section

1.5 mm

2

Protection DIN EN 60529

IP 65 face with seal

Operation / keypad

Membrane with softkeys

Housing type

Built-in housing

Dimensions W x H x L 48 x 48 x 108 mm

Installation depth

108 mm

Mounting

Clip frame

Cutout dimensions

45 x 45 mm (+0.6)

Materials

Housing: Makrolon 6485 (PC)

Keypad: Polyester

Weight approx.

140 g