TE1/TE2 - Pt100 Temperature System

TE1

temperature-

sensor or

transmitter

TE2

temperature

sensor

Use only the recommended sleeves or adapters. If other systems are
used, there is a severe risk of system malfunction or untight process
connections.
Do not use Teflon, elastomere or other types of gaskets for the
hygienic process connection featuring a conical seal.
The tightening torque is 10...20 Nm.

Mechanical Installation - Mounting Examples

Mounting a Welding Part

10...20 Nm.

The hygienic welding parts are easy to weld into tank walls and pipes.
The mark or hole on the welding part indicates the final position of the
cable gland or M12 connector for a TE1/TE2 sensor.
We recommend to position the gland or plug downwards in order to
avoid water intrusion.

Check the tightness of the process connection. Make sure that the
cable gland or the M12 plug connector is properly screwed in.

Mark

M12 connection

No thread

G1/2A hygienic

PM031

CAM020

TE2

temperature

transmitter

Safety instructions

This instrument is built and tested according to the current EU-direc-
tives and packed in technically safe condition. In order to maintain this
condition and to ensure safe operation, the user must follow the hints
and warnings given in this instruction.

During the installation the valid national rules have to be observed.
Ignoring the warnings may lead to severe personal injury or substan-
tial damage to property.

The product must be operated by trained staff. Correct and safe op-
eration of this equipment is dependent on proper transport, storage,
installation and operation.

All electrical wiring must conform to local standards. In order to
prevent stray electrical radiation, we recommend twisted and shielded
input cables, as also to keep power supply cables separated from the
input cables. The connection must be made according to the connect-
ing diagrams.

Before switching on the power supply take care that other equipment
is not affected. Ensure that the supply voltage and the conditions in
the environment comply with the specification of the device.

Before switching off the supply voltage check the possible effects on
other equipment and the processing system.

WARNING

This product contains no replaceable parts.
In case of malfunction the product must be shipped to Baumer for
repair.

10...20 Nm.