beautypg.com

Baumer RXA1H User Manual

Page 31

background image

Manual_ProCam_V1-10_EN.doc

31/35

Baumer IVO GmbH & Co. KG

10.05.11

Villingen-Schwenningen,

Germany

Start cam program


Clicking on the "Start" button starts the selected program. All
outputs programmed as cam outputs assume the state
corresponding to the cam position.

Time cams are treated as "Time
expired" during the program start.
Direction cams are set during the
program start with the encoder stopped
as if the encoder had last run in the
positive direction. Positive is the rotating
direction in which the position values
increase. (See Chapter 4.2.2 "Counting
direction" for setting).

Information window during
start




Stop cam program
Clicking on the "Stop" button stops the running program. All cam outputs assume the inactive
state. The inactive state is de-energized for non-inverted outputs, and +UB for inverted
outputs.
The outputs programmed with a special function (e.g. run control, speed monitoring) are
always active.